HTR-150T-XYZ-A Automatic Rockwell hardness tester

HTR-150T-XYZ-A  Automatic Rockwell hardness tester
HTR-150T-XYZ-A  Automatic Rockwell hardness tester
HTR-150T-XYZ-A  Automatic Rockwell hardness tester


Product introduction:

1. All Rockwell and surface Rockwell scales can be measured

2. Conduct the force test according to the standard.

3. The z-axis of the worktable rises and falls automatically, and the x-axis and Y-axis directions of the

sample table move automatically.

4. Press the start key, the worktable will rise automatically, the sample will be loaded and unloaded

automatically after touching the indenter, and the hardness value will be displayed automatically;

Automatically move to the next measurement point for automatic measurement.

5. According to the standard hardness block, each hardness scale is automatically corrected in three

sections: high, medium and low.

6. Measure any point on any sample within the range of 100mm * 100mm.

7. High precision X / y automatic mobile station is adopted, and the repetition accuracy is 0.005 mm.

8. Set measuring points, conduct multi-point full-automatic testing, batch testing, and greatly improve

the efficiency.

9. Various fixtures can be customized for batch testing of different samples.

10. The database processing function is powerful, including: HR, Hb, HV and other hardness system

conversion, setting the qualified range, exceeding the limit automatic alarm, and inputting the tester,sample name and other information. The measurement parameters and data are automatically saved

to the database.

11. When the hardness tester host is used independently, the data USB flash disk is directly saved in

Excel format for easy editing and processing.

12. The product is designed and produced by itself, has independent intellectual property rights and

software copyright, and can be customized and upgraded for a long time.

Technical Parameters:

Model

HTR-150T-XYZ-A

HTR-150/45T-XYZ-A

Initial test force

10kgf(98.07N)

10kgf(98.07N) 3.0kgf(29.4N)

Total test force

60kgf(588N)
100kgf(980N)
150kgf(1471N)

60kgf(588N)
100kgf(980N)
150kgf(1471N)
15kgf(147.1N)
30kgf(294.2N)
45kgf(441.3N)

Hardness scale

HRA、HRB、HRC、
HRD、HRE、HRF、
HRG、HRH、HRK、
HRL、HRM、HRR、
HRP、HRS、HRV

HRA、HRB、HRC、HRD、HRE、HRF、
HRG、HRH、HRK、 HRL、HRM、
HRR、HRP、HRS、HRV
15N、15T、15W、15X、15Y、30N、
30T、30W、30X、30Y、45N、45T 、
45W、45X、45Y

Test scope

HRA:20-88、HRB:20-
100 、HRC:20-70 、
HRD:40-77 、HRE:70-
100 、HRF:60-100 、
HRG:30-94、HRH:80-
100、HRK:40-100、
HRL:100-120 HRM:85-
115、 HRR:114-125

HRA:20-88、HRB:20-100 、HRC:20-
70 、HRD:40-77 、HRE:70-100 、
HRF:60-100 、HRG:30-94、HRH:80-
100、HRK:40-100、HRL:100-120
HRM:85-115、 HRR:114-125
HR15N:70-94 HR30N:42-86 HR45N:
20-77
HR15T:67-93 HR30T:29-82 HR45T:
1-72

standard

GB/T230 , ISO 6508, ASTM E18, BSEN 6508

Duration Time

0-99s


Hardness value
resolution

0.1HR

Test force error

<1.0%

data output

LCD display

Exchange Scales

Surface Rockwell, Brinell
and Vickers

Rockwell, Superficial Rockwell, Brinell,
Vickers

Maximum
allowable
specimen height

300mm for ordinary sample table; 200mm with X mobile station; 100mm
for X / y mobile station

Distance from
indenter to
machine wall

200mm

X / y motor table
stroke:

100mm(optional: 200mm)

Accuracy of X / y
motor table:

0.005mm

size

560×280×850mm

weight

80kg

Power Supply

AC220+5%,50~60Hz,600W



Lascia un messaggio

Puoi anche contattarmi via e-mail. Il mio indirizzo e-mail è admin@hssdtest.com

Quotazione rapida: